Socomec meters, connected properly.
Diris meters measure far more than most installations ever ask them for. Reading the full register map rather than three headline values is where the value is.
Socomec Diris meters are common in commercial and industrial switchboards and are capable instruments: full three phase measurement, energy accumulation and, on the higher models, power quality data. A large proportion of the ones we encounter have never been connected to a network.
We also do a lot of work with the DIRIS MCM multi circuit range. An MCM-16 or MCM-48 puts sixteen or forty eight metered circuits inside one enclosed unit, using 333 mV split core or Rogowski sensors, which makes it a practical way to submeter a building without finding panel space for dozens of individual meters. It is revenue grade, so it holds up for tenant billing.
Integration is over Modbus TCP where the meter has an Ethernet module, or Modbus RTU over RS-485 where it does not. RTU is frequently the cheaper route for meters already installed, since a daisy chain to a single gateway avoids running Ethernet to every panel.
The details matter more than the protocol. CT ratios have to match what is physically installed, register data types and byte order have to be read correctly, and scaling factors are usually buried in an appendix. Getting any of those wrong produces readings that look plausible and are wrong by a factor of ten.
We have a partnership with a Socomec distributor, so we can supply the meters and current sensors as well as integrate them, one quote instead of sourcing hardware separately. We are not tied to Socomec, though. Where another meter suits the job better, or the ones you already own are perfectly capable, we will say so.
Socomec integration detail
- Diris A series, A10, A20, A40, A41 and related models
- Diris MCM-16 and MCM-48, enclosed multi circuit submeters
- Diris Digiware, Diris B and G series, and Countis energy meters
- Modbus TCP over Ethernet, Modbus RTU over RS-485
- Full register map read, not just headline values
- CT ratio and sensor verification as part of commissioning
- Mixed estates, Socomec alongside other brands in one system
What this involves.
Multi circuit submetering
DIRIS MCM-16 and MCM-48 bring sixteen or forty eight circuits onto the network from a single enclosed meter, the usual answer for retrofits where panel space is tight.
Real time dashboards
Live kW, voltage, current, power factor and demand from every Diris on the network.
Energy trends
kWh accumulation trended over time, broken down by meter, area or tenant.
Reports & billing
PDF summaries and CSV export, including tenant statements backed by interval data.
Have Socomec meters that are not connected?
That is one of the least expensive monitoring projects available. Send us the model numbers.